Description
T3SSK7528D TROVE3SS3/S2/28DR/ULX/PTC
Altronix T3SSK7528D kit consists of Trove3 enclosure, TSS3 Lenel-S2 (S2 Security Platform)/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 12VDC @ 10A power supply/charger, four (4) PTC access power controllers, and two (2) PTC power distribution modules.
This kit also accommodates two (2) S2-INST Installation Kit sFor Lenel-S2 (S2 Security Platform) S2 Network Node for up to twenty-eight (28) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger - 1 Input Voltage: 115VAC, 60Hz, 4.2A max. Main Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. AL1012ULXB Power Supply/Charger - 2 Input Voltage: 115VAC, 60Hz, 2.6A max. Fusing: 5A / 250V. Output Voltage: 12VDC. Current: 10A @ 12VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Both Power Supplies Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. Three (3) ACM8CB Access Power Controllers Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled PTC outputs for each ACM8CB a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4CB Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A/32V. Outputs Voltage: 24VDC. Four (4) 24VDC independently controlled PTC outputs for ACM4: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators LED Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Two (2) PD16WCB Power Distribution Modules Input Voltage: 12VDC from AL1012ULXB. Outputs Voltage: 12VDC. Output PTCs: 2.5A. Indicators LED Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.
This kit also accommodates two (2) S2-INST Installation Kit sFor Lenel-S2 (S2 Security Platform) S2 Network Node for up to twenty-eight (28) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger - 1 Input Voltage: 115VAC, 60Hz, 4.2A max. Main Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. AL1012ULXB Power Supply/Charger - 2 Input Voltage: 115VAC, 60Hz, 2.6A max. Fusing: 5A / 250V. Output Voltage: 12VDC. Current: 10A @ 12VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Both Power Supplies Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. Three (3) ACM8CB Access Power Controllers Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled PTC outputs for each ACM8CB a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4CB Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A/32V. Outputs Voltage: 24VDC. Four (4) 24VDC independently controlled PTC outputs for ACM4: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators LED Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Two (2) PD16WCB Power Distribution Modules Input Voltage: 12VDC from AL1012ULXB. Outputs Voltage: 12VDC. Output PTCs: 2.5A. Indicators LED Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.