Description
T3M77XK2D T3MK77F16SD/PWX/KIT2
Altronix T3M77XK2D is a 14-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T3M77XK2D accommodates one (1) Intelligent Dual Reader Controller and seven (7) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt Two (2) eFlow104NB Power Supply/Chargers Input Voltage: 120VAC, 60Hz, 9A max. Input Fuse: 6.3A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Protection: Overvoltage protection. Filtered and regulated. Battery Charging Type: Sealed lead acid or gel type. Fuse Rating: 15A/32VDC. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED AC Input: 120VAC is present. DC Output: 24VDC is present Battery: Discharged or not connected. Two (2) VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. Two (2) ACMS8CB Access Power Controllers Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6. Input PTC: 9A. Outputs Voltage: 12VDC or 24VDC individually selectable. Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated. c) Auxiliary power outputs (unswitched). d) Any combination of the above. Any of the eight (8) PTC protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Blue LED: FACP disconnect is triggered. Individual voltage LEDs: Green: 12VDC. Red: 24VDC. Two (2) PDS8CB Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow104NB Input PTC: 9A Outputs Voltage: 12VDC and/or 24VDC Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2 Individual outputs may be set to OFF position for servicing Outputs Ratings PTCs: 2.5A. Indicators LED DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt Two (2) eFlow104NB Power Supply/Chargers Input Voltage: 120VAC, 60Hz, 9A max. Input Fuse: 6.3A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Protection: Overvoltage protection. Filtered and regulated. Battery Charging Type: Sealed lead acid or gel type. Fuse Rating: 15A/32VDC. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED AC Input: 120VAC is present. DC Output: 24VDC is present Battery: Discharged or not connected. Two (2) VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. Two (2) ACMS8CB Access Power Controllers Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6. Input PTC: 9A. Outputs Voltage: 12VDC or 24VDC individually selectable. Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated. c) Auxiliary power outputs (unswitched). d) Any combination of the above. Any of the eight (8) PTC protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Blue LED: FACP disconnect is triggered. Individual voltage LEDs: Green: 12VDC. Red: 24VDC. Two (2) PDS8CB Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow104NB Input PTC: 9A Outputs Voltage: 12VDC and/or 24VDC Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2 Individual outputs may be set to OFF position for servicing Outputs Ratings PTCs: 2.5A. Indicators LED DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.