Description
T3M7724XK1D T3MK77F24SD/PWX/KIT1
Altronix T3M7724XK1D is a 24-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T3M7724XK1D accommodates up to one (1) Intelligent Dual Reader Controller and eleven (11) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
*Also compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.
Two (2) eFlow104NB Power Supply/Chargers
Input
Voltage: 120VAC, 60Hz, 9A max
Main Fuse: 6.5A / 250V.
Output
Voltage: 24VDC @ 10A.
Auxiliary: 1A (unswitched).
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 12VDC/12AH (4 within enclosure), 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type.
Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non-latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
AC Input: 120VAC is present.
DC Output: 24VDC is present
Battery: Discharged or not connected.
Two (2) ACMS12CB Dual Input Access Power Controllers
Input
Voltage: 24VDC from eFlow104NB and 12VDC from VR6.
Input PTCs: 9A.
Outputs
Voltage: 12VDC and/or 24VDC.
Twelve (12) independently controlled PTC outputs:
a) Fail-Safe and/or Fail-Secure power outputs.
Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Outputs Ratings
PTCs: 2.5A.
Indicators (LED's)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
Two (2) VR6 Voltage Regulators
Input
Voltage: 24VDC from eFlow104NB.
Output
Voltage: 12VDC.
Current: 6A continuous.
Other: Surge suppression.
Indicators LED
Input: 24VDC is present.
Output: Powered.
Two (2) PDS16CB Dual Input Power Distribution Modules
Input
Voltage: 24VDC from eFlow104NB and 12VDC from VR6
Input PTCs: 9A.
Outputs
Voltage: 12VDC and/or 24VDC.
Any of the sixteen (16) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Output PTCs: 2.5A.
Indicators (LED)
DC Output: Sixteen (16) individual output LEDs.
Green: 12VDC
Red: 24VDC.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
289 BTU/Hr.