Description
T3M7724XK1 T3MK77F24S/PWX/KIT1
Altronix T3M7724XK1 is a 24-door access and power integration kit which includes Altronix
power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T3M7724XK1 accommodates up to one (1) Intelligent Dual Reader Controller and eleven (11) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
*Also compatible with these authentic Mercury partners: AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt. Two (2) eFlow104NB Power Supply/Chargers Input Voltage: 120VAC, 60Hz, 9A max Main Fuse: 6.5A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (4 within enclosure), 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type. Fuse Rating: 15A/32V. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED AC Input: 120VAC is present. DC Output: 24VDC is present Battery: Discharged or not connected. Two (2) ACMS12 Dual Input Access Power Controllers Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6. Input Fuse: 15A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Twelve (12) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Outputs Ratings Fuses: 3A/32V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Two (2) VR6 Voltage Regulators Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. Two (2) PDS16 Dual Input Power Distribution Modules Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6 Main Fuse: 15A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the sixteen (16) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A / 32V. Indicators (LED) DC Output: Sixteen (16) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.
*Also compatible with these authentic Mercury partners: AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt. Two (2) eFlow104NB Power Supply/Chargers Input Voltage: 120VAC, 60Hz, 9A max Main Fuse: 6.5A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (4 within enclosure), 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type. Fuse Rating: 15A/32V. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED AC Input: 120VAC is present. DC Output: 24VDC is present Battery: Discharged or not connected. Two (2) ACMS12 Dual Input Access Power Controllers Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6. Input Fuse: 15A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Twelve (12) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Outputs Ratings Fuses: 3A/32V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Two (2) VR6 Voltage Regulators Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. Two (2) PDS16 Dual Input Power Distribution Modules Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6 Main Fuse: 15A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the sixteen (16) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A / 32V. Indicators (LED) DC Output: Sixteen (16) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 289 BTU/Hr.