Description
T3KAK3316D TROVE3KA3/16DR/12A/ULX/PTC
Altronix T3KAK3316D kit consists of Trove3 enclosure and TKA3 Keyscan/Altronix door backplane with two (2) 12 or 24VDC @ 6A power supply/chargers, two (2) 8-output PTC access power controllers, one (1) 4-output PTC power distribution module and one (1) 16VAC transformer.
This kit also accommodate various combinations of Keyscan boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. Two (2) AL600ULXB Power Supply/Chargers Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Output Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. Two (2) ACM8CB Access Power Controllers Input Voltage: 24VDC from AL600ULXB. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled PTC outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD4ULCB Power Distribution Module Input Voltage: 24VDC from T16175. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 16VAC. Output PTCs: 2.5A. Indicators (LED) Green LED: DC Output. T16175 Transformer Input Voltage: 115VAC, 50/60Hz, 1.6A. Output Voltage: 16VAC/175VA. 11A supply current. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 152 BTU/Hr.
This kit also accommodate various combinations of Keyscan boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. Two (2) AL600ULXB Power Supply/Chargers Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Output Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. Two (2) ACM8CB Access Power Controllers Input Voltage: 24VDC from AL600ULXB. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled PTC outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD4ULCB Power Distribution Module Input Voltage: 24VDC from T16175. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 16VAC. Output PTCs: 2.5A. Indicators (LED) Green LED: DC Output. T16175 Transformer Input Voltage: 115VAC, 50/60Hz, 1.6A. Output Voltage: 16VAC/175VA. 11A supply current. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 152 BTU/Hr.