Description
T3HWK75F16V TROVE3HW3, HW 16-DR FUSE 220V
Altronix T3HWK75F16V kit consists of Trove3 enclosure, THW3 Honeywell/Altronix backplane and THWD2 Honeywell/Altronix door backplane with one (1) 24VDC @ 10A and one (1) 12VDC @ 10A power supply/chargers, two (2) 8-output fused access power controllers and one (1) 8-output fused power distribution module. Also featured is a rocker switch bracket with two (2) rocker switches.
Kit also accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8 boards for up to sixteen (16) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow104NBV Power Supply/Charger - 1 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A. Main Fuse: 6.5A / 250V. Output Voltage: 24VDC. Current: 10A continuous. eFlow102NBV Power Supply/Charger - 2 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A. Main Fuse: 5A / 250V. Output Voltage: 12VDC. Current: 10A continuous. Both Power Supplies Outputs Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure) 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units or 71-73% for 12V units. Prevents deep battery discharge. Indicators (LED) AC Input: 220VAC is present. DC Output: Powered. Two (2) ACM8 Access Power Controllers Input Voltage: 24VDC from eFlow104NBV. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD8UL Power Distribution Module Input Voltage: 12VDC from eFlow102NBV. Outputs Voltage: 12VDC. Eight (8) fuse protected outputs. 3.5A per output max. Output Fuses: 3.5A / 250V. Indicators (LED) Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 177 BTU/Hr.
Kit also accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8 boards for up to sixteen (16) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow104NBV Power Supply/Charger - 1 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A. Main Fuse: 6.5A / 250V. Output Voltage: 24VDC. Current: 10A continuous. eFlow102NBV Power Supply/Charger - 2 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A. Main Fuse: 5A / 250V. Output Voltage: 12VDC. Current: 10A continuous. Both Power Supplies Outputs Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure) 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units or 71-73% for 12V units. Prevents deep battery discharge. Indicators (LED) AC Input: 220VAC is present. DC Output: Powered. Two (2) ACM8 Access Power Controllers Input Voltage: 24VDC from eFlow104NBV. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD8UL Power Distribution Module Input Voltage: 12VDC from eFlow102NBV. Outputs Voltage: 12VDC. Eight (8) fuse protected outputs. 3.5A per output max. Output Fuses: 3.5A / 250V. Indicators (LED) Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 177 BTU/Hr.