Altronix T3HW75XK1DQ2 is a 16-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Honeywell hardware. This unit provides ample power and dual voltage outputs to support Honeywell platform controllers and locking devices. The T3HW75XK1DQ2 accommodates up to one (1) Intelligent Controller and seven (7) Dual Reader Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
eFlow104NB Power Supply/Charger - 1
Input
Voltage: 120VAC, 60Hz, 4.5A.
Input Fuse: 6.3A / 250V.
Output
Voltage: 24VDC @ 10A.
Auxiliary: 1A (unswitched).
Protection: Overvoltage protection. Filtered and regulated.
eFlow102NB Power Supply/Charger - 2
Input
Voltage: 120VAC, 60Hz, 3.5A.
Input Fuse: 5A / 250V.
Output
Voltage: 12VDC @ 10A.
Auxiliary: 1A (unswitched).
Protection: Overvoltage protection. Filtered and regulated.
Both Power Supplies
Battery Charging
Capacity 12VDC/12AH (4 within enclosure); 40AH/65AH (requires separate enclosure).
Type: Sealed lead acid or gel type.
Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non-latching.
EOL 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
AC Input: 120VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
LINQ2 Network Communication Module
Status Monitoring
AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection Input trigger state change; Output (relay and power supply) state change
Programming
Battery service date indication
Programmable via USB or web browser
Automated timed events:
- Control output relays and power supply via flexible timing parameter
Reporting
Programmable dashboard notifications
E-mail notification selectable by event
Event log tracks history (100+ events)
Indicators (LED)
Blue LED: Power ON
Two (2) ACMS8CB Dual Input Access Power Controllers
Input
Voltage: 24VDC from eFlow104NB and 12VDC from eFlow102NB.
Input PTC: 9A.
Outputs
Voltage: 12VDC or 24VDC individually selectable.
Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs:
a) Fail-Safe and/or Fail-Secure power outputs.
b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated.
c) Auxiliary power outputs (unswitched).
d) Any combination of the above.
Any of the eight (8) PTC protected power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Outputs Ratings
PTCs: 2.5A.
Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).
Blue LED: FACP disconnect is triggered.
Individual voltage LEDs:
Green: 12VDC.
Red: 24VDC.
Two (2) PDS8CB Dual Input Power Distribution Modules
Input
Voltage: 24VDC from eFlow104NB and 12VDC from eFlow102NB.
Input PTC: 9A.
Outputs
Voltage: 12VDC and/or 24VDC.
Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Outputs Ratings
PTCs: 2.5A.
Indicators (LED)
DC Output: Eight (8) individual output LEDs
Green: 12VDC
Red: 24VDC
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
263 BTU/Hr.