Description
T2SK78 TROVE2SH2/FUSE/8DR/ULXB
Altronix T2SK78 kit consists of Trove2 enclosure, TSH2 Software House/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module.
This kit also accommodates various combinations of Software House boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC 60Hz, 4.2A max. Main Fuse: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from AL1024ULXB2. Main Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A / 32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 128 BTU/Hr.
This kit also accommodates various combinations of Software House boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC 60Hz, 4.2A max. Main Fuse: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from AL1024ULXB2. Main Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A / 32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 128 BTU/Hr.