Altronix T2MK7F8Q TROVE2M2, 8-DR, 10A, FUSE, LQ2

AltronixSKU: T2MK7F8Q

Price:

Login to see pricing

MSRP:
$1,928.67
Stock:
Call for availability

Description

T2MK7F8Q TROVE2M2, 8-DR, 10A, FUSE, LQ2 Altronix T2MK7F8Q kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 24VDC @ 10A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) fuse protected output dual voltage power distribution module and eight (8) fuse protected output access control module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow104NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 4.5 max. Input Fuse: 6.3A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Protection: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. LINQ2 Network Communication Module Status Monitoring AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection. Input trigger state change; Output (relay and power supply) state change. Programming Battery service date indication. Programmable via USB or web browser. Automated timed events: - Control output relays and power supply via flexible timing parameter. Reporting Programmable dashboard notifications. E-mail notification selectable by event. Event log tracks history (100+ events). Indicators LED Blue LED: Power ON. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow104NB. Input Fuse: 10A/32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 87 BTU/Hr.

You may also like

Recently viewed