Altronix T2MK75F16Q TROVE2M2, 12/24, 20A, FUSE, LQ

AltronixSKU: T2MK75F16Q

Price:

Login to see pricing

MSRP:
$2,486.14
Stock:
Call for availability

Description

T2MK75F16Q TROVE2M2, 12/24, 20A, FUSE, LQ Altronix T2MK75F16Q kit consists of Trove2 enclosure, TM2 Mercury/Altronix backplane and TMV2 door backplane with 24VDC @ 10A and 12VDC @ 10A power supply/chargers, Network communication module, sixteen (16) fuse protected output power distribution module and two eight (8) fuse protected output access control modules. This kit also accommodates various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow104NB Power Supply/Charger - 1 Input Voltage: 120VAC, 60Hz, 4.5A max. Main Fuse: 6.3A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Protection: Overvoltage protection. Filtered and regulated. eFlow102NB Power Supply/Charger - 2 Input Voltage: 120VAC, 60Hz, 3.5A max. Main Fuse: 5A / 250V. Output Voltage: 24VDC @ 10A. Auxiliary: 1A (unswitched). Protection: Overvoltage protection. Filtered and regulated. Both Power Supplies Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Indicators LED AC Input: 24VDC is present. DC Output: Powered. Battery: Discharged or not connected. LINQ2 Network Communication Module Status Monitoring AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection. Input trigger state change; Output (relay and power supply) state change. Programming Battery service date indication. Programmable via USB or web browser. Automated timed events: - Control output relays and power supply via flexible timing parameter. Reporting Programmable dashboard notifications. E-mail notification selectable by event. Event log tracks history (100+ events). Indicators LED Blue LED: Power ON. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD16W Power Distribution Module Input Voltage: 12VDC from eFlow102NB. Output Voltage: 12VDC. Fuses: 3.5A/250V. Indicators LED Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 217 BTU/Hr.

You may also like

Recently viewed