Description
T2MK3F8DQ TROVE2M2, 8-DR, 6A, PTC, LQ2
Altronix T2MK3F8DQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) PTC protected output dual voltage power distribution module and eight (8) PTC protected output access control module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz. Input Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 6A continuous. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. LINQ2 Network Communication Module Status Monitoring AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection. Input trigger state change; Output (relay and power supply) state change. Programming Battery service date indication. Programmable via USB or web browser. Automated timed events: - Control output relays and power supply via flexible timing parameter. Reporting Programmable dashboard notifications. E-mail notification selectable by event. Event log tracks history (100+ events). Indicators LED Blue LED: Power ON. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow6NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. PDS8CB Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow6NB. Input PTC Rating: 9A. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings PTCs: 2.5A. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. ACM8CB Access Power Controller Input Voltage: 24VDC from eFlow6NB. Main Fuse: 10A / 250V. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 24VDC. Eight (8) 24VDC independently controlled PTC outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 87 BTU/Hr.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz. Input Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 6A continuous. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. LINQ2 Network Communication Module Status Monitoring AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection. Input trigger state change; Output (relay and power supply) state change. Programming Battery service date indication. Programmable via USB or web browser. Automated timed events: - Control output relays and power supply via flexible timing parameter. Reporting Programmable dashboard notifications. E-mail notification selectable by event. Event log tracks history (100+ events). Indicators LED Blue LED: Power ON. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow6NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. PDS8CB Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow6NB. Input PTC Rating: 9A. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings PTCs: 2.5A. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. ACM8CB Access Power Controller Input Voltage: 24VDC from eFlow6NB. Main Fuse: 10A / 250V. Outputs Class 2 power-limited auto-resettable outputs. Voltage: 24VDC. Eight (8) 24VDC independently controlled PTC outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 87 BTU/Hr.