Description
T2MK3F8 TROVE2M2, 8-DR, 6A, FUSED
Altronix T2MK3F8 kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, 12VDC voltage regulator, eight (8) fuse protected output dual voltage power distribution module and eight (8) fuse protected output access control module. This kit also accommodate various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz. Input Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 6A continuous. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (Up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow6NB. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A / 32V. Indicators LED DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow6NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow6NB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 87 BTU/Hr.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz. Input Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 6A continuous. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (Up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow6NB. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A / 32V. Indicators LED DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow6NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow6NB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 87 BTU/Hr.