Description
T2KSK712 TROVE2KS2/12DR/10A ULX/FUSE
Altronix T2KSK7F12 kit consists of Trove2 enclosure, TKS2 Keri Systems/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) dual output fused access power controller, one (1) voltage regulator, one (1) dual input fused power distribution module, and one (1) fused access power controller.
This kit also accommodate various combinations of Keri Systems boards for up to twelve (12) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC 60Hz, 4.2A max. Main Fuse: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. ACM4 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A / 32V. Outputs Voltage: 24VDC. Four (4) independently controlled 2.5A outputs: a) Four (4) Fail-Safe and/or Fail-Secure power outputs. b) Four (4) dry form “C” 5A rated relay outputs. c) Any combination of the above. Four (4) auxiliary power outputs (unswitched). Outputs Ratings Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACMS8 Dual Input Access Power Controller Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Input Fuse: 15A / 32V. Outputs Voltage: 12 or 24VDC individually selectable. Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated. c) Auxiliary power outputs (unswitched). d) Any combination of the above. Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Blue LED: FACP disconnect is triggered. Individual voltage LEDs: Green: 12VDC. Red: 24VDC. PDS8 Dual Input Power Distribution Module Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC or 24VDC individually selectable. Output Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC. Red: 24VDC. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 131 BTU/Hr.
This kit also accommodate various combinations of Keri Systems boards for up to twelve (12) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC 60Hz, 4.2A max. Main Fuse: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. ACM4 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A / 32V. Outputs Voltage: 24VDC. Four (4) independently controlled 2.5A outputs: a) Four (4) Fail-Safe and/or Fail-Secure power outputs. b) Four (4) dry form “C” 5A rated relay outputs. c) Any combination of the above. Four (4) auxiliary power outputs (unswitched). Outputs Ratings Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACMS8 Dual Input Access Power Controller Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Input Fuse: 15A / 32V. Outputs Voltage: 12 or 24VDC individually selectable. Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated. c) Auxiliary power outputs (unswitched). d) Any combination of the above. Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Blue LED: FACP disconnect is triggered. Individual voltage LEDs: Green: 12VDC. Red: 24VDC. PDS8 Dual Input Power Distribution Module Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC or 24VDC individually selectable. Output Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC. Red: 24VDC. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 131 BTU/Hr.