Description
T2KK38D TROVE2KA2/8DR/6A/ULXB/PTC
Altronix T2KK38D kit consists of Trove2 enclosure, TKA2 Keyscan/Altronix backplane with one (1) 24VDC @ 6A power supply/charger, one (1) PTC access power controller, and one (1) 16VAC transformer.
This kit also accommodate various combinations of Keyscan boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL600ULXB Power Supply/Charger Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Output Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure). Type: Sealed lead acid or gel type. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. T16100 Transformer Input Voltage: 115VAC, 50/60Hz, 1A. Output Voltage: 16VAC/100VA. 6.25A supply current. ACM8CB Access Power Controller Input Voltage: 24VDC from AL600ULXB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 111 BTU/Hr.
This kit also accommodate various combinations of Keyscan boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL600ULXB Power Supply/Charger Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Output Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (up to 2 within enclosure); 40 AH / 65 AH (requires separate enclosure). Type: Sealed lead acid or gel type. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. T16100 Transformer Input Voltage: 115VAC, 50/60Hz, 1A. Output Voltage: 16VAC/100VA. 6.25A supply current. ACM8CB Access Power Controller Input Voltage: 24VDC from AL600ULXB. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 111 BTU/Hr.