Description
T2HWK712V TROVE2HW2/12DR/10A/ULX/FUS/220
Altronix T2HWK712DV kit consists of Trove2 enclosure, THW2 Honeywell/Altronix backplane, THWD2 Honeywell door backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output PTC access power controller, one (1) 4-output PTC access power controller, one (1)
voltage regulator and one (1) 8-output PTC dual input power distribution module.
THW2 backplane also accommodates up to three (3) Honeywell 4200 Series or WIN-PAK Series boards and up to one (1) Honeywell PW7K1ICE, PW7K1R1E boards for up to twelve (12) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8/PW5K1MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024XB2V Power Supply/Charger Input Voltage: 220VAC (working range 198VAC-256VAC), 50/60Hz, 2.5A. Fusing: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 220VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from AL1024XB2V. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024XB2V. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024XB2V. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4 Access Power Controller Input Voltage: 24VDC from AL1024XB2V. Input Fuse: 10A /32V. Outputs Voltage: 24VDC. Four (4) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 128 BTU/Hr.
THW2 backplane also accommodates up to three (3) Honeywell 4200 Series or WIN-PAK Series boards and up to one (1) Honeywell PW7K1ICE, PW7K1R1E boards for up to twelve (12) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8/PW5K1MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024XB2V Power Supply/Charger Input Voltage: 220VAC (working range 198VAC-256VAC), 50/60Hz, 2.5A. Fusing: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 220VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from AL1024XB2V. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024XB2V. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024XB2V. Input Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED's) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4 Access Power Controller Input Voltage: 24VDC from AL1024XB2V. Input Fuse: 10A /32V. Outputs Voltage: 24VDC. Four (4) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 128 BTU/Hr.