T2CVK33F10Q TROVE2CV2, 10-DR, 12A,PTC,LQ2
Altronix T2CVK33F10Q kit consists of Trove2 enclosure, TCV2 CDVI/Altronix backplane with two (2) 12 or 24VDC @ 6A power supply/chargers, one (1) network communication module and two (2) PTC protected five (5) output Power Distribution Modules with Fire Alarm Interface. This kit also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to ten (10) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Two (2) eFlow 6NB Power Supply/Chargers
Input
Voltage: 120VAC, 60Hz, 3.5A max.
Fusing: 5A / 250V.
Output
Voltage: 12VDC or 24VDC selectable.
Current: 6A continuous max.
Auxiliary: Power-limited @ 1A (unswitched).
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Type: Sealed lead acid or gel type.
Fuse Rating: 10A @ 32VDC.
Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non-latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
Input: 120VAC is present.
DC Output: Powered.
LINQ2 Network Communication Module
Status Monitoring
AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection.
Input trigger state change; Output (relay and power supply) state change.
Programming
Battery service date indication.
Programmable via USB or web browser.
Automated timed events: - Control output relays and power supply via flexible timing parameter.
Reporting
Programmable dashboard notifications.
E-mail notification selectable by event.
Event log tracks history (100+ events).
Indicators (LED)
Blue LED: Power ON.
Two (2) MOM5 Power Distribution Modules with Fire Alarm Interface
Input
Voltage: 12VDC or 24VDC from power supply.
Output
Five (5) individual Class 2 Rated PTC protected power-limited outputs (auto-resettable).
Voltage: 12VDC or 24VDC.
Current: 2.5A continuous supply current. Current limit is 2A per output.
Other: Short circuit and thermal overload protection. Filtered and regulated.
Fire Alarm Interface
Fire Alarm Panel or Access Control System trigger inputs N.O. or N.C. supervised trigger input and polarity reversal trigger input.
Supervision
Power Failure: Form “C” contact rated 1A 28VDC/115VAC.
Trigger: Form “C” contact rated 1A 28VDC/115VAC.
Indicators (LED)
Input: Power is present.
Input Trigger: On.
Outputs (Individual LEDs): Output fail.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 74 BTU/Hr.
24VDC: 148 BTU/Hr.