Altronix T1SAK34 TROVE1SA1/12/24VDC@6A/FUSE/ULX

AltronixSKU: T1SAK34

Price:

Login to see pricing

MSRP:
$1,168.19
Stock:
Call for availability

Description

T1SAK34 TROVE1SA1/12/24VDC@6A/FUSE/ULX Altronix T1SAK34 kit consists of Trove1 enclosure, TSA1 Salto/Altronix backplane with one (1) 12VDC or 24VDC @ 6A power supply/charger, one (1) fused access power controller, one dual input power distribution module and one (1) voltage regulator. This kit also accommodates up to two (2) Salto CU42E0, CU4200 or CU4EB8 modules for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL600ULXB Power Supply/Charger Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Outputs Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12VDC/7AH (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from AL600ULXB. Main Fuse Rating: 10A / 32V. Output Voltage: 12VDC and/or 24VDC. Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A / 32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL600ULXB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators (LED) Input: 24VDC is present. Output: Powered. ACM4 Access Power Controller Input Voltage: 24VDC from AL600ULXB. Fusing: 10A / 32V. Output Voltage: 24VDC. Four (4) independently controlled 2.5A outputs: a) Four (4) Fail-Safe and/or Fail-Secure power outputs. b) Four (4) dry form “C” 5A rated relay outputs. c) Any combination of the above. Four (4) auxiliary power outputs (unswitched). Outputs Ratings Fuses: 3A / 32VDC. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 12VDC: 40 BTU/Hr. 24VDC: 77 BTU/Hr.

You may also like

Recently viewed