Description
T1M1LCK3D T1MK14SD/MAG/ULX/PTC/115
Altronix T1M1LCK3D is a 4-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury* hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T1M1LCK3D accommodates two (2) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
AL400ULXB2 Power Supply/Charger
Input
Voltage: 115VAC, 60Hz, 3.5A max.
Input Fuse: 5A / 250V.
Outputs
Voltage: 12VDC or 24VDC selectable.
Current: 4A @ 12VDC or 3A @ 24VDC continuous max.
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 12VDC/7AH (2 within enclosure); 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Indicators LED
Input: 115VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
PDS8CB Dual Input Power Distribution Module
Input
Voltage: 12VDC from VR6 and 24VDC from AL400ULXB2.
Input PTC: 9A.
Outputs
Voltage 12VDC and/or 24VDC.
Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Outputs Ratings
PTCs: 2.5A.
Indicators LED
DC Output: Eight (8) individual output LEDs.
Green: 12VDC
Red: 24VDC.
VR6 Voltage Regulator
Input
Voltage: 24VDC from AL400ULXB2.
Output
Voltage: 12VDC.
Current: 6A continuous.
Other: Surge suppression.
Indicators LED
Input: 24VDC is present.
Output: Powered.
ACM4CB Access Power Controller
Input
24VDC from AL400ULXB2.
Input Fuse: 10A / 32V.
Outputs
Voltage: 24VDC.
Four (4) independently controlled 2.5A outputs:
a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
b) Any combination of the above.
Four (4) auxiliary power outputs (unswitched).
Outputs Ratings
PTCs: 2.5A.
Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
90 BTU/Hr.