Description
T1KE34DV TROVE1 ULX/KISI 4DR/PTC/220V
Altronix T1KE34DV kit consists of Trove1 enclosure and TDR1 Altronix & Kisi backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger and four (4) PTC protected output access control modules. This kit also accommodates various combinations of Kisi boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
AL600XB220 Power Supply/Charger
Input
Voltage: 220VAC (range 198VAC-256VAC), 50/60Hz, 1.5A. max
Input Fuse: 5A / 250V.
Outputs
Voltage: 12VDC or 24VDC selectable.
Current: 6A @ 12VDC or 24VDC continuous max.
Other: Filtered and regulated.
Battery Charging
Capacity: 7AH / 12VDC (Up to 4 within enclosure); 12AH / 12VDC (requires separate enclosure); 40 AH / 65 AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Indicators LED
Input: 220VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
ACM4CB Access Power Controller
Input
Voltage: 24VDC from AL600XB220.
Input Fuse: 10A / 32V.
Outputs
Voltage: 24VDC.
Four (4) independently controlled 2.5A outputs:
a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
b) Any combination of the above.
Four (4) auxiliary power outputs (unswitched).
Outputs Ratings
PTCs: 2.5A.
Indicators (LED's)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):