Altronix AL1024NK8QP 24 & 12VDC@6A/8FUSE LINQ8/115V

AltronixSKU: AL1024NK8QP

Price:

Login to see pricing

MSRP:
$1,177.29
Stock:
Call for availability

Description

Altronix AL1024NK8QP 24 & 12VDC@6A/8FUSE LINQ8/115V Altronix AL1024NK8QP sub-assembly kit converts a 115VAC 60Hz input into eight (8) fuse protected outputs. Outputs are individually selectable, providing 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power) for access control panels, door locks, and ancillary devices. Unit also offers a suite of features that includes overvoltage protection, AC fail supervision, low battery supervision and battery presence supervision. Networkable power distribution module facilitates monitoring, reporting, and control of the supervised DC power supply/charger over the network. It reports diagnostics via Email and Windows Dashboard Alert notifications, greatly reducing system downtime and eliminating unnecessary service calls. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC, 60Hz, 4.2A max. Input Fuse: 5A / 250V. Outputs Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Protection: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure); 40 AH / 65 AH (requires separate enclosure). Type: Sealed lead acid or gel type. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. LINQ8PD Network Power Distribution Module Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Input Fuses: 15A/32V. Outputs Eight (8) fuse protected outputs rated 2.5A. Power output(s) can be locally or remotely controlled. Surge suppresion. Output Fuses: 3A/32V. Status Monitoring Power Supply output voltage and load. Voltage and load of each output. FACP trigger and reset status. Unit temperature (Celsius). Power Supply AC and Battery status. Battery health. Indicators (LED) Bat Local: Charging current status. FACP: Triggered / Released. Input: Input signal. Out1 - Out8: Bi-colored LEDs indicate 12 or 24VDC. Reporting Windows Dashboard Alert messages. E-mail notifications. Event Log tracks history. Programming Features Power Supply(ies) voltage and load limits (High/Low). FACP trigger type (wet or dry-N.O./N.C.). Input Function (FACP reset/tamper). Output Reset Trigger (N.O./N.C.). Battery Monitor Configuration: - Battery condition (Low/Normal/Missing). - Service Date. Configurable Output Relay(s). Individual Output Configuration: - Device ID. - Voltage and Current Limits (High/Low). - FACP Trigger Setting (latching/non-latching/inactive). - Battery Backup. Fire Alarm Interface Supervised FACP disconnect (Latching or Non-Latching). FACP reset (N.C. or N.O.). Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 123 BTU/Hr.

You may also like

Recently viewed